Description
Pair of motor brushes for H.MH-130 or H.MH-13018 in K.1030 or H-103018 Portable Micromotor Kits
Pay careful attention to the orientation of the brush curve in relation to the curve of the motor armature. The same orientation must be maintained when replacing brushes. Replace both brushes with new ones even if only one of them looks worn. Brushes should be check for wear every 200 hours of use and replaced when the brush is less than 2mm (5/64") long.